NC 90 HES SERIES
-
NC 90 HES WS | Inward opening
Water tightness
EN 1027, EN 12208Class: E750 Air permeability
EN 1026 - EN 12207Class: 4 Resistance to wind load
EN 12211 - EN 12210B5/C5 Soundproofing power
EN ISO 10140-3
EN ISO 717-1Up to 48dB Burglar resistance
EN 1627 - EN 1630RC3 Operating forces
EN 13115 - EN 120461 Mechanical resistance
EN 131154 Resistance to repeated
opening and closing cycles
EN1191 - EN 124003 Resistance to impact
EN 130495 Uf Value
EN ISO 10077-2Uf Value 0,84-1,8 W/m2K Uw Value
EN ISO 10077-10,8 Ug [W/m2K]
Reference dimensions [mm]
1230x14800,6 Psi [W/mK]
Reference dimensions [mm]
1230x14800,031 Environmental Product
Declaration - EPDITALY0254Water tightness
EN 1027, EN 12208Class: E750 Air permeability
EN 1026 - EN 12207Class: 4 Resistance to wind load
EN 12211 - EN 12210B5/C5 Soundproofing power
EN ISO 10140-3
EN ISO 717-1Up to 48dB Burglar resistance
EN 1627 - EN 1630RC3 Operating forces
EN 13115 - EN 120461 Mechanical resistance
EN 131154 Resistance to repeated
opening and closing cycles
EN1191 - EN 124003 Resistance to impact
EN 130495 Uf Value
EN ISO 10077-2Uf Value 0,84-1,8 W/m2K Uw Value
EN ISO 10077-10,8 Ug [W/m2K]
Reference dimensions [mm]
1230x14800,6 Psi [W/mK]
Reference dimensions [mm]
1230x14800,031 Environmental Product
Declaration - EPDITALY0254Fixed Window
1 side hung casment
WindowTilt-and-turn
Window2 side hung casements
Window2 casement with
tilt and turn WindowVasistas Window
Tilting-sliding window
Horizontal and vertical
pivot window1 side hung casment
Casement doorTilt-and-turn
Casement door2 side hung casements
Casement door2 casement with
tilt and turn Casement door -
NC 90 HES WX | Outward opening
Water tightness
EN 1027, EN 12208Class: 9A Air permeability
EN 1026 - EN 12207Class: 9A Resistance to wind load
EN 12211 - EN 12210B3/C3 Uf Values
EN ISO 10077-2Uf Value 1,1-2,0 W/m2K Uw Values
EN ISO 10077-10,9 Ug [W/m2K]
Reference dimensions [mm]
1230x14800,6 Psi [W/mK]
Reference dimensions [mm]
1230x14800,031 Environmental Product
Declaration - EPDITALY0254Water tightness
EN 1027, EN 12208Class: 9A Air permeability
EN 1026 - EN 12207Class: 9A Resistance to wind load
EN 12211 - EN 12210B3/C3 Uf Values
EN ISO 10077-2Uf Value 1,1-2,0 W/m2K Uw Values
EN ISO 10077-10,9 Ug [W/m2K]
Reference dimensions [mm]
1230x14800,6 Psi [W/mK]
Reference dimensions [mm]
1230x14800,031 Environmental Product
Declaration - EPDITALY02541 casement outward
opening windowsProjecting Window
2 casement outward
opening window1 casement outward
opening Casement door2 casement outward
opening Casement door -
NC 90 HES HL | Concealed opening
Water tightness
EN 1027, EN 12208Class: E750 Air permeability
EN 1026 - EN 12207Class: 4 Resistance to wind load
EN 12211 - EN 12210B5/C5 Uf Value
EN ISO 10077-21,1 ÷ 2,4 Uw Value
EN ISO 10077-10,8 Ug [W/m2K]
Reference dimensions [mm]
1230x14800,6 Psi [W/mK]
Reference dimensions [mm]
1230x14800,031 Environmental Product
Declaration - EPDITALY0254Water tightness
EN 1027, EN 12208Class: E750 Air permeability
EN 1026 - EN 12207Class: 4 Resistance to wind load
EN 12211 - EN 12210B5/C5 Uf Value
EN ISO 10077-21,1 ÷ 2,4 Uw Value
EN ISO 10077-10,8 Ug [W/m2K]
Reference dimensions [mm]
1230x14800,6 Psi [W/mK]
Reference dimensions [mm]
1230x14800,031 Environmental Product
Declaration - EPDITALY0254Fixed Window
1 side hung casment
WindowTilt-and-turn
Windowv2 side hung casements
Window2 casement with
tilt and turn WindowVasistas Window
Tilting-sliding window
1 side hung casment
Casement doorTilt-and-turn
Casement door2 side hung casements
Casement door2 casement with
tilt and turn Casement door -
NC 90 HES NA WX | Outward opening
1 casement outward
opening windows2 casement outward
opening window1 casement outward
opening Casement door2 casement outward
opening Casement door